Ören Digital RG6 U/6 Trishield
CCS/Cu
Class B
Application Area
This type of RG6 cables is used for indoor CATV distributions, and connections of SMATV systems which require low attenuations.
Cable Construction
Inner Conductor
Ø 1.02 mm Copper Clad Steel
Insulation 
Ø 4.60 mm Gas Injected
Skin/Foam/Skin PE
1st Shielding
Copper Foil
Bonded to the insulation
2nd Shielding 
Annealed Copper Wire Braiding
3rd Shielding 
Copper Foil
Bonded to the Outer Sheath
Outer Sheath
Ø 6.80 mm PVC, HFFR* or PE
Technical Properties
Min. Bending Radius 30 mm
Max. Tensile Strength 210N
Operating Temperature -30 °C ... + 70 °C
Packing 100 / 300 / 500 m
Electrical Properties
Impedance 75+3 Ω
Capacitance 53 + 2 pF/m
Velocity of Propagation 84  %
Insulation Resistance > 2 GΩxkm
Operating Voltage 1300 V
Test Voltage 3000 V
Inner Conductor DCR < 95.00 Ω/km
Attenuations (20°C)
5 MHz 1.80 dB/100m
50 MHz 4.60 dB/100m
230 MHz 9.25 dB/100m
470 MHz 14.60 dB/100m
860 MHz 19.80 dB/100m
1000 MHz 21.60 dB/100m
1200 MHz 23.05 dB/100m
2150 MHz 32.40 dB/100m
3000 MHz 39.05 dB/100m
Return Loss (20°C)
5-470 MHz > 26 dB
470-1200 MHz > 23 dB
1200-2000 MHz > 20 dB
2000-3000 MHz > 18 dB
Transfer Impedance
5-30 MHz 15mΩ/m
Screen Attenuation
30-1200 MHz ≥ 75 dB
1200-2000 MHz ≥ 65 dB
2000-3000 MHz ≥ 55 dB
 
Standards
Screening Class Class B
EN 50117-2-4  
EN 50117-2-5  
Product
Name
Outer Sheath
Material
Euro
Class
Cable
Weight
Flame
Retardancy
Corrosive Gases
Test
Smoke
Density
Download
Data Sheet
Ören Digital RG6 U/6 CCS/Cu Trishield  PVC Eca 49 kg/km EN 60332-1-2 N/A N/A PVC
Ören Digital RG6 U/6 CCS/Cu Trishield HFFR HFFR Dca 50 kg/km EN 60332-1-2 EN 50267-2-3 EN 61034-2 HFFR
Ören Digital RG6 U/6 CCS/Cu Trishield PE PE Fca 41 kg/km N/A N/A N/A  PE