RG6 U/6 Trishield AP
Cu/Cu
Application Area
This type of RG6 cables is used for outdoor and aerial distributions of CATV networks and connections of SMATV systems
which require low attenuations.
Cable Construction
|
Inner Conductor |
|
Ø 1.02 mm Bare Copper |
|
Insulation |
Ø 4.60 mm Gas Injected
Skin/Foam/Skin PE |
|
1st Shielding |
|
Cu-Pet Foil |
|
2nd Shielding |
|
Annealed Copper Wire Braiding |
|
3st Shielding |
|
Cu-Pet Foil |
|
Suspension Wire |
|
Ø 1.20mm Galvanized Steel |
|
Outer Sheath |
|
Ø 6.80 - 10.60 mm PE |
Technical Properties
|
Copper Weight |
15.85 kg/km |
|
Min. Bending Radius |
30 mm |
|
Max. Tensile Strength |
60 N |
|
Operating Temperature |
-40 °C ... + 70 °C |
|
Packing |
300 / 500 /1000 m |
Electrical Properties
|
Impedance |
75+3 Ω |
|
Capacitance |
53 + 2 pF/m |
|
Velocity of Propagation |
84 + 2 % |
|
Insulation Resistance |
> 2 GΩxkm |
|
Operating Voltage |
1300 V |
|
Test Voltage |
3000 V |
|
Inner Conductor DCR |
< 22.10 Ω/km |
Attenuations (20°C)
|
5 MHz |
1.85 dB/100m |
|
50 MHz |
4.65 dB/100m |
|
230 MHz |
9.25 dB/100m |
|
470 MHz |
14.40 dB/100m |
|
860 MHz |
19.40 dB/100m |
|
1000 MHz |
21.30 dB/100m |
|
1200 MHz |
23.05 dB/100m |
|
2150 MHz |
32.10 dB/100m |
|
3000 MHz |
39.05 dB/100m |
Return Loss (20°C)
|
5-470 MHz |
> 26 dB |
|
470-1200 MHz |
> 23 dB |
|
1200-2000 MHz |
> 20 dB |
|
2000-3000 MHz |
> 18 dB |
Transfer Impedance
Screen Attenuation
|
30-1200 MHz |
≥ 85 dB |
|
1200-2000 MHz |
≥ 75 dB |
|
2000-3000 MHz |
≥ 65 dB
|
Standards
|
Screening Class |
Class A |
|
EN 50117-2-5 |
|
Product
Name |
Outer Sheath
Material |
Euro
Class |
Cable
Weight |
Flame
Retardancy |
Corrosive Gases
Test |
Smoke
Density |
Download
Data Sheet |
|
RG6 U/6 AP Cu/Cu PE |
PE |
Fca |
56 kg/km |
N/A |
N/A |
N/A |
PE |