HBAPH
Application Area
These cables, which are used as subscriber distribution cables in telephone lines in fixed installations in buildings for data communication purposes, are available in HFFR insulation and HFFR jacketed version.
Cable Construction
Inner Conductor
Ø 0.50 mm, Bare Copper Wire
Insulation
HFFR, Color Coded, TS IEC 60189-2 70°C,
EN 50290-2-26
Pairs
Cores are stranded to pairs.
Stranding
Cores are stranded to pairs
These quintets are seperated by Pet foil and creates groups.
These groups are stranded together for more than 20 pairs.
Polyester
Pet Band 100% Coverage
Drain Wire
Ø 0.50 mm Tinned Copper Wire
Foil
Al-Pet Foil 100% Coverage
Outer Sheath
HFFR, RAL 7001 Gri
EN 50290-2-27
Technical Properties
Operating Temperature -30°C … + 70°C
Operating Voltage 250 V
Test Voltage 1000 V
Insulation Resistance 500 MΩ km
Conductor Resistance 97.8 Ω/km
Max. Capacitance 56 nF/km
Max. Capacitance Unbalance 400 pF / 500m
Min. Bending Radius 10 x D
Packing 500 / 1000m

Standards
TSE K 116
Euro Class
Eca
Flame Retardart Test
EN 60332-1-2
Smoke Density
EN 61034-2
Korrosve Gase Test
EN 50267-2-3 
No. Of Cores x Cross Section
(mm)
Overall Diameter
(mm)
Copper Weight
(kg/km)
Approx. Weight
(kg/km)
    1 x 2 x 0.50 + 0.50 3.3 5.6 20
    2 x 2 x 0.50 + 0.50 4.0 9.3 28
    3 x 2 x 0.50 + 0.50 4.2 12.9 35
    4 x 2 x 0.50 + 0.50 5.0 16.9 43
    5 x 2 x 0.50 + 0.50 5.4 20.8 49
    6 x 2 x 0.50 + 0.50 5.8 24.5 57
  10 x 2 x 0.50 + 0.50 8.1 40.0 92
  20 x 2 x 0.50 + 0.50 10.1 80.0 158
  30 x 2 x 0.50 + 0.50 12.1 119.0 223
  50 x 2 x 0.50 + 0.50 15.2 197.0 355
100 x 2 x 0.50 + 0.50 20.2 392.0 647