VBAVB
Application Area
These cables, which are used as subscriber distribution cables in telephone lines in fixed installations in buildings for data communication purposes, are available in PVC insulation and PVC jacketed version.
Cable Construction
Inner Conductor
Ø 0.50 mm, Bare Copper Wire
Insulation
Semi rigid PVC, Color Coded,
TS IEC 60189-2 70°C, EN 50290-2-21 TM52
Pairs
Cores are stranded to pairs.
Stranding
Pairs are stranded together up to 10 pairs.
These quintets are seperated by Pet foil and creates groups.
These groups are stranded together for more than 20 pairs.
Polyester
Pet Band 100% coverage
Drain Wire
Ø 0.50 mm Tinned Copper Wire
Foil
Al-Pet Foil 100% coverage
Polyester
Pet Band
Outer Sheath
PVC, RAL 7001 Gri
EN 50290-2-22 TM52
Technical Properties
Operating Temperature -30°C … + 70°C
Operating Voltage 250 V
Test Voltage 1000 V
Insulation Resistance 5000 MΩ km
Conductor Resistance 97.8 Ω/km
Max. Capacitance 56 nF/km
Max. Capacitance Unbalance 400 pF / 500m
Min. Bending Radius 10 x D
Packing 100 / 500 / 1000m

Standards
TSE K 116
Euro Class
Eca
Flame Retardart Test
EN 60332-1-2
No. Of Cores x Cross Section
(mm)
Overall Diameter
(mm)
Copper Weight
(kg/km)
Approx. Weight
(kg/km)
    1 x 2 x 0.50 + 0.50 3.3 5.6 19
    2 x 2 x 0.50 + 0.50 4.0 9.3 27
    3 x 2 x 0.50 + 0.50 4.2 12.9 34
    4 x 2 x 0.50 + 0.50 5.0 16.9 42
    5 x 2 x 0.50 + 0.50 5.4 20.8 48
    6 x 2 x 0.50 + 0.50 5.8 24.5 56
  10 x 2 x 0.50 + 0.50 8.1 40.0 91
  20 x 2 x 0.50 + 0.50 10.1 80.0 157
  30 x 2 x 0.50 + 0.50 12.1 119.0 222
  50 x 2 x 0.50 + 0.50 15.2 197.0 354
100 x 2 x 0.50 + 0.50 20.2 392.0 646