Data Sheet İndir
EC400 Cat 6 SF/UTP
Application Area
10Base-T, 100Base-T, 1000Base-T, and Fieldbus systems. Applicable for Power over Ethernet (PoE) / PoE+
Cable Construction
• 23 AWG Bare Copper 
• PE Insulation
• Pair Seperator
• Al-Pet Foil 100% Coverage
•Tinned Copper Wire Braiding 
•Ø 7.10 ± 0.20 mm PVC, LSZH or PE Jacket
Standards
EIA/TIA-568
ISO/IEC 11801 Class E
IEC 61156-5 , EN 50173-1
EN 50288-5-1
Technical Properties
Copper Weight 24.4 kg/km
Min. Bending radius    during draw in 60 mm
Min. Bending radius    permanently installed 30 mm
Max. Tensile Strength 90 N
Min. Crush Resistance 1000 N/10 cm
Min. Impact 10 Impacts
Installation Temperature 0°C … + 50°C
Operating Temperature -20°C … + 70°C
Packing 305 / 500 m
Electrical Properties                              at 20ºC   
Max. Conductor Resistance < 9.5 Ω / km
Max. Resistance Unbalance < 2%
Min. Insulation Resistance 5000 MΩ x m
Mutual Capacitance < 60 pF / m
Max. Capacitance Unbalance 1600 pF / km
Impedance at 100 MHz 100 ± 5 Ω
Velocity of Propagation 67 %
Delay Skew < 45 ns / 100 m
Coupling Attenuation > 70 dB
Segregation Class C
Transfer Impedance at 1/10/30MHz < 10/10/30 mΩ/m
Test Voltage 1000 V
Operating Voltage 125 V
Product Name Euro Class Cable Weight Flame Retardancy Corrosive Gases  Smoke Density Download
Data Sheet
EC400 CAT 6 SF/UTP PVC Eca Eca 63 Kg/Km EN 60332-1-2 N/A N/A Download
EC400 CAT 6 SF/UTP LSZH Dca Dca 65 Kg/Km EN 60332-1-2 EN 50267-2-3 EN 61034-2 Download
EC400 CAT 6 SF/UTP PE Fca Fca 53 Kg/Km N/A N/A N/A Download
Frequency 
(MHz)
Attenuation 
(dB/100 m)
NEXT
(dB)
PS - NEXT
(dB)
ACR
(dB/100 m)
PS-ACR
(dB/100 m)
ACRF
(dB/100 m)
PS-ACRF
(dB/100 m)
Return Loss
(dB)
1 2.0 83 80 85 82 83 80 25
4 3.6 73 70 70 67 70 67 31
10 6.0 73 70 65 62 60 57 30
100 19.5 55 52 40 37 35 32 25
200 28.5 50 47 25 22 30 27 22
250 32.0 45 42 25 22 22 19 22
300 33.0 40 37 15 12 20 17 22
400 39.0 40 37 7 4 20 17 20