EC600 Cat 7 S/FTP
Application Area
10Base-T, 100Base-T, 1000Base-T, 10GBase-T, and Filedbus systems. Applicable for Power over Ethernet PoE / PoE+
Cable Construction
• 23 AWG Bare Copper 
• Skin/Foam/Skin PE Insulation
• Al-Pet Foil 100% Coverage
• Tinned Copper Wire Braiding 
• Ø 7.30 ± 0.20 mm LSZH or PE Jacket
Standards
EIA/TIA-568
ISO/IEC 11801 Class F
IEC 61156-5 , EN 50173-1
EN 50288-4-1
Technical Properties
Copper Weight 21.9 kg/km
Min. Bending radius    during draw in 60 mm
Min. Bending radius    permanently installed 30 mm
Max. Tensile Strength 90 N
Min. Crush Resistance 1000 N/10 cm
Min. Impact 10 Impacts
Installation Temperature 0°C … + 50°C
Operating Temperature -20°C … + 70°C
Packing 305 / 500 m
Electrical Properties                                       at 20ºC   
Max. Conductor Resistance < 9.5 Ω / km
Max. Resistance Unbalance < 2%
Min. Insulation Resistance 5000 MΩ x m
Mutual Capacitance < 56 pF / m
Max. Capacitance Unbalance 1600 pF / km
Impedance at 100 MHz 100 ± 5 Ω
Velocity of Propagation 76 %
Delay Skew < 25 ns / 100 m
Coupling Attenuation  > 70 dB
Segregation Class  C
Transfer Impedance at 1/10/30 MHz < 10/10/30 mΩ/m
Test Voltage 1000 V
Operating Voltage 125 V
Product Name Euro Class Cable Weight Flame Retardancy Corrosive Gases  Smoke Density Download
Data Sheet
EC600 CAT 7 S/FTP LSZH Eca Eca 56 Kg/Km EN 60332-1-2 EN 50267-2-3 EN 61034-2 Download
EC600 CAT 7 S/FTP LSZH Cca Cca 56 Kg/Km EN 60332-1-2 EN 50267-2-3 EN 61034-2 Download
EC600 CAT 7 S/FTP PE Fca Fca 49 Kg/Km N/A N/A N/A Download
Frequency 
(MHz)
Attenuation 
(dB/100 m)
NEXT
(dB)
PS - NEXT
(dB)
ACR
(dB/100 m)
PS-ACR
(dB/100 m)
ACRF
(dB/100 m)
PS-ACRF
(dB/100 m)
Return Loss
(dB)
1 2.0 104 101 99 96 101 98 24
4 3.4 104 101 97 94 98 95 30
10 4.9 101 98 95 92 98 95 32
100 17.3 100 97 82 79 84 81 34
250 28.2 95 92 63 60 70 67 27
500 42.0 95 92 56 53 61 58 24
600 44.0 88 85 45 42 59 56 22
700 53.5 84 81 30 27 52 49 20
800 55.5 83 80 28 25 50 47 19
900 57.3 80 77 23 20 49 46 18
1000 59.1 77 75 23 20 48 45 18