Data Sheet İndir
EC200 Cat 5e SF/UTP
Application Area
10Base-T, 100Base-T, 1000Base-T systems. Applicable for Power over Ethernet (PoE) / PoE+
Cable Construction
• 24 AWG Bare Copper 
• PE Insulation
• Al-Pet Foil 100% Covarage
• Tinned Copper Wire Braiding
• Ø 6.20 ± 0.20 mm LSZH or PE Jacket
Standards
EIA/TIA-568
ISO/IEC 11801 Class D
IEC 61156-5 , EN 50173-1
EN 50288-2-1
Technical Properties
Copper Weight 20 kg/km
Min. Bending radius during draw in 50 mm
Min. Bending radius permanently installed 25 mm
Max. Tensile Strength 90 N
Min. Crush Resistance 1000 N/10 cm
Min. Impact 10 Impacts
Installation Temperature 0°C … + 50°C
Operating Temperature -20°C … + 70°C
Packing 305 / 500 m
Electrical Properties                                       at 20ºC   
Max. Conductor Resistance < 9.5 Ω / km
Max. Resistance Unbalance < 2%
Min. Insulation Resistance 5000 MΩ x m
Mutual Capacitance < 60 pF / m
Max. Capacitance Unbalance 1600 pF / km
Impedance at 100 MHz 100 ± 5 Ω
Velocity of Propagation 66 %
Delay Skew < 45 ns / 100 m
Test Voltage 1000 V
Operating Voltage 125 V
Product Name Euro Class Cable Weight Flame Retardancy Corrosive Gases  Smoke Density Download
Data Sheet
EC200 CAT 5e SF/UTP LSZH Eca Eca 48 Kg/Km EN 60332-1-2 N/A N/A Download
EC200 CAT 5e SF/UTP LSZH Dca Dca 48 Kg/Km EN 60332-1-2 EN 50267-2-3 EN 61034-2 Download
EC200 CAT 5e SF/UTP PE Fca Fca 42 Kg/Km N/A N/A N/A Download
Frequency 
(MHz)
Attenuation 
(dB/100 m)
NEXT
(dB)
PS - NEXT
(dB)
ACR
(dB/100 m)
PS-ACR
(dB/100 m)
ACRF
(dB/100 m)
PS-ACRF
(dB/100 m)
Return Loss
(dB)
1 2.0 70 67 68 65 78 75 21
4 3.6 62 59 58 55 70 67 29
10 5.7 55 52 50 47 52 49 30
16 7.7 55 52 45 42 50 47 30
31.2 11.2 48 45 40 37 35 32 29
62.5 16.4 48 45 30 27 35 32 27
100 20.9 40 37 20 17 30 27 27
200 27.3 35 32 10 7 20 17 20